Summary of Instructions AFA-AWG20L
For first-time usage: The AFA-AWG20L must be in vertical position 24 hours before using. Keep the machine running till the water level on the screen to reach 3/4, then drain all water from the 2 water outlets (white plastic nut cap) which located at the back middle part of the machine when you use the machine at the first time. Be careful with the hot water from the hot water outlet. Do not forget to change filters periodically.
!! Important !! Please note the below is a summary of instructions. We refer to the full instructions which can be downloaded as a PDF at the bottom of this page.
1. This appliance is intended to be used in household and similar applications such as: (lEC60335-2-15) staff kitchen areas in shops, offices and other working environments; farm houses; by clients in hotels, motels and other residential type environments; -bed and breakfast type environments.
2. Appliances can be used by persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
3. Do not store explosive substances such as aerosocans with a flammable propellant in this appliance.
4. Children shall not play with the appliance. Cleaning and maintenance shall not be done by children.
5. No installation required for AFA-AWG20L, just plug into the power source and follow the instructions in this manual. It is easy to operate, environmentally friendly, clean and healthy.
Limitation of Liability
All technical information, data, wiring and operating instructions contained in this product manual correspond to the latest state of the art at the time of printing and have been made to the best of our knowledge and experience. No claims can be derived from the data, illustrations, and descriptions in this product manual. Supplier is not liable for damages resulting from non-observance of the product manual, improper use, improper repairs, unauthorized changes, or the use of unauthorized spare parts.
Fields of Application
AFA-AWG20L is designed exclusively for the water production from air above 15°C and minimum 30% humidity environment condition. Our recommendation is to use the AFA-AWG20L in indoor environments, but with constant and free access to fresh air. If AFA-AWG20L is used outdoors, please ensure it is in a safe and dry location, choose your placement and location carefully. If not chosen properly; it could lead to injuries and/or machine damage, Supplier is not liable for any damage caused by improper use or placing.
#2 Safety notes
2.1. The electrical outlet shall be equipped with a reliable and correct grounding
2.2. Do not disconnect the grounding plug from the power cord
2.3. Do not use an extension cord or power adapter
2.4. Do not use damaged power cords or plugs
2.5. Always turn off the 20L AWG by unplugging the power cord before servicing
2.6. Do not plug in or unplug the power cord with wet hands
2.7. Do not share the power outlet with other machines
2.8. Only use replacements/consumables supplied by supplier
2.9. Improper repairing will not be protected by warranty policy
2.10. Unplug the power cord and empty the water from all tanks before moving 20L AWG
2.11. Do not tilt the 20L AWG more than 20° while moving it. If tilted more than 20°, it must remain in an upright position for at least 24 hours before re-connecting to the power supply
2.12. Avoid prolonged eye contact with the LED-UV lamp
2.13. Warm water is heated to 85°C, please keep your body and skin away from the hot water to avoid injuries
2.14. CAUTION – LED-UV light source - disconnect the power supply from the LED-UV before opening the cover
2.15. CAUTION - TO AVOID RISK OF FIRE OR ELECTRIC SHOCK, USE THE MACHINE ONLY INDOOR. SEE FURTHER INFO IN PRODUCT MANUAL
2.16. Install away from toxic gases or aggressive liquids
#3 Precautions
3.1. It is forbidden to install and use 20L AWG in areas where there is a risk of explosion.
3.2. It is forbidden to install and use 20L AWG in areas where the air contains oil, sulfur, chlorine or salt.
3.3. This 20L AWG is not intended for outdoor not properly roofed areas
3.4. It is forbidden to wash 20L AWG with a jet of water
3.5. Do not place any objects on the 20L AWG
3.6. It is forbidden to cover the intake and exhaust ports
3.7. It is forbidden to insert any objects into 20L AWG
3.8. It is forbidden to cover or move the switched-on 20L AWG
3.9. Operate 20L AWG in an upright vertical position
3.10. All electrical cables must be secured against damage
3.12. The switching voltage must not fall below 10% of the standard supply to avoid increased noise or overheating. If this happens, disconnect 20L AWG from the power supply immediately until the voltage returns to normal
3.14. Position 20L AWG in an area where it will not hinder or injure people by hitting the machine or spill water in the lower tank and cause an E7 error (see 14. Trouble shooting)
3.15. The 20L AWG can only be operated in a vertical position, and the machine must be completely empty before each operation (see 13. Complete drainage)
3.16. Please follow product manual for detailed instructions before using 20L AWG
3.18. In case of non-observance of these instructions, supplier is not liable for any damages and the warranty cannot be applied
Important electrical connection information
AFA-AWG20L must be connected to the power source in accordance with current standards for power supplies equipped with static circuit breakers. If AFA-AWG20L is used in damp areas, the machine must be equipped with a static electricity circuit breaker which shall be provided by user to meet the conditions of such areas.
-
#4 Description of features
1. AFA-AWG20L uses an eight-stage filtration process to produce clean drinking water from the air. 20L AWG extracts air through the ① Air filter which can prevent micro particles and dust entering into machine.
-
2. The cleaned air and water vapor go inside and contact with the evaporator where the water vapor freeze due to compressor refrigerant in coils.
-
3. Subsequently, the reverse function of the compressor heats up and the ice condenses into water, which drips into the water bowl of stainless steel, flows into the lower stainless steel tank, equipped with a ⑦LED UV lamp to remove bacteria and microorganisms.
-
4. Hi-tech pump and water processing The hi-tech pump pushes the water through a comprehensive filtration system, including the Softening filter (SFT), the Sediment filter (PPF), and the Ultrafiltration membrane filter (UF). The water further progresses through the Pre-carbon filter (GAC) and the Electropositive Membrane filter (ELE). Finally, the water is pumped into an upper stainless steel tank equipped with an additional LED UV lamp to ensure that no bacteria or microorganisms remain.
Two stainless steel tanks are located under the upper tank: one heats the purified drinking water to 85°C and the other cools it to 6°C. Note: AFA-AWG20L has an option to connect to an additional water source to ensure a constant supply of clean drinking water even in periods of low humidity. Read more about this in the full Instructions.
Note: AFA-AWG20L has 1 option of connecting to an additional water source to ensure that it can provide a constant supply of clean drinking water in all conditions even in periods of low humidity, which is not suitable for a normal operation. Read more about this in the full Instructions.
-
#5 Test features
It is important to note that the actual performance is based on physical laws, which depends on the relative humidity ("RH") and ambient temperature. RH is ubiquitous and penetrates through all porous materials. In general, the higher RH and ambient temperature, the higher amount of water will be produced. Water production is determined according to the table right / below. More info in the full Instructions.
Components (#6)
6.1. Microcomputer - controls water production, collection, filtration, storage, heating, cooling and distribution of water that this device generates from the air
6.2. Electronic sensor - controls LED UV lamp, temperature, water levels, energy efficiency, maintenance, security and other features 6.3. Sensors for saving energy - control the process of making water from air with maximal efficiency
6.4. Hot water lock- prevents accidental dispensing of hot water from AFA-AWG20L
6.5. Venturi blower - designed to provide maximum efficiency and reduced noise levels
6.6. Water leak detector - in case leaking, AFA-AWG20L will stop working and automatically displays error E7 on control panel (see 14. Trouble shooting)
6.7. Connection set - a set of water hoses can be connected directly
to the tap or supply pipe, which allows AFA-AWG20L to function as a water purifier using a device filtering and disinfection system. Additional installation instructions (see 12. Connection of additional water sources)
6.8. Power switch - control the total power supply of AFA-AWG20L. AFA-AWG20L start to work when it is turned on and stop working when it is turned off.
6.9. Hot water switch - hot water function, make sure that the hot water switch (red) is switched to "ON" position UP. Water heating switch must be turned on for at least 30 minutes, then the water can be heated to 85°C.
6.10. Cold water switch - cold water function, make sure that the cold water switch (black) is switched to "ON" position UP. Cold water switch must be turned on for at least 30 minutes, then the water can be cooled to 6°C.
6.11. 8-step filtering process: The fan system extracts air and pushes it through the air filter. Water vapor in the air contacts the stainless steel coils and condensation occurs, producing water. The water then passes through the following 7 filtration steps to remove chlorine, fluoride, lead, and other harmful ingredients, producing up to 20 liters of clean drinking water per day:
① Air filter: Prevents dust and micro-particles from entering the device and cleans the air.
② Softening filter (SFT): Softens water by removing calcium, magnesium ions, etc.
③ Sediment filter (PPF): Eliminates dirt and particles with a diameter over 5 microns.
④ Ultrafiltration Membrane filter (UF): Ultrafine filter that eliminates particles smaller than 0.01 microns.
⑤ Pre-carbon filter (GAC): Charcoal and coconut shells absorb hazardous organic compounds, such as chlorine, pesticides, and volatile organic compounds.
⑥ Electropositive Membrane filter (ELE): Uses adsorption (electro-adhesion) with an absolute rating of 0.2 microns to filter viruses, bacteria, colloids, and trace pharmaceuticals.
⑦ LED UV Lamp: Kills bacteria and microorganisms (located in the lower tank).
⑧ LED UV Lamp: Kills any remaining bacteria and microorganisms (located in the upper tank).
6.12. Recirculated water - our exclusive technology ensures clean water recirculating through the internal water filters every 6 hours, so that the stored water always remains fresh and drinkable.
6.13. Protection against overheating - overheating protection will automatically switches AFA-AWG20L off when it detects overheating.
6.14. Protection against refrigerant leakage - AFA-AWG20L will be automatically switches off if refrigerant leak is detected.
Continue reading the full instructions
If you are looking for more detailed information about the AFA-AWG20L, on how to operate it, trouble shooting or how to
perform small or medium maintenance; please download the full Instruction guide via the link below.